Technical parameters of Vacuum Circuit Breaker
The vacuum circuit breaker specifications are as follows.
Table 1-Circuit Breaker Rated Technical Data
No. | Name | Unit | Parameter | |
1 | Rated voltage | kV | 11 and 33 | |
2 | 1 min rated power frequency withstand voltage | up to 70 | ||
3 | Rated lightning impulse withstand voltage (peak) | 170 | ||
4 | Rated current | A | up to 630 | |
5 | Rated frequency | Hz | 50/60 | |
6 | Rated short-circuit breaking current | kA | 12.5 | |
7 | Rated short-circuit making a current (peak) | 31.5 | ||
8 | Rated peak withstand current | 31.5 | ||
9 | Rated short-time withstand current (4s) | kA | 12.5 | |
10 | Rated operating sequence | O-0.3s-CO-180s-CO | ||
11 | Closing time | ms | 25-60 | |
12 | Opening time | 18-45 | ||
13 | Breaking times for rated short-circuit breaking current | times | 30 | |
14 | Mechanical life | 10000 | ||
15 | Secondary circuit 1min power frequency withstand voltage | V | 2000 | |
16 | Charging motor rated power | W | 40 | |
17 | Charging motor rated voltage | V | DC24 | |
18 | Rated closing operation voltage | DC24 | ||
19 | Rated opening operation voltage | DC24 | ||
20 | Motor charging time | s | ≤12 | |
21 | Weight | Circuit breaker | kg | 130 |
A circuit breaker with dis-connector | 165 |
Table 2 – Main Mechanical Characteristics of Circuit Breaker
No. | Name | Unit | Parameter |
1 | Contact travel | mm | 12-14 |
2 | Contact over-travel | 2-4 | |
3 | Phase Distance (Center to Center) | 410±2 | |
4 | Contact closing bounce time | ms | ≤3 |
5 | Three-phase open/close synchronism | ≤2 | |
6 | Average opening speed | m/s | 1.2-1.6 |
7 | Average closing speed | 0.6-1.0 | |
8 | Resistance of the main circuit | μΩ | ≤200 |
Table 3 – Main Technical Data of Dis-connector
No. | Name | Unit | Parameter | |
1 | Rated voltage | kV | 11 and 33 | |
2 | Rated current | A | up to 630 | |
3 | Frequency | Hz | 50/60 | |
4 | Short-time withstand current (4s) | kA | 12.5 | |
5 | Rated peak withstand current | 31.5 | ||
6 | 1min power frequency withstand voltage | Across open contacts | kV | 70 |
7 | Circuit resistance | μΩ | ≤120 | |
8 | Center deviation value of three-phase insulating closing | mm | ≤2 | |
9 | Synchronism deviation value of three-phase insulator open/close | ≤2 | ||
10 | Insulating distance between conductor to earth | ≥300 | ||
11 | Contact travel | ≥260 |
Table 4 – Operating Mechanism Characteristics
No. | Name | Unit | Parameter | No. |
1 | Opening coil | DC24 | 7 | Reliable tripping under 65%-120% rated voltage, no tripping less than 30% rated voltage |
DC110 | 5 | |||
AC220 | 3.5 | |||
DC220 | 1.8 | |||
2 | Closing coil | DC24 | 7 | Reliable tripping under65%-120% rated voltage |
AC220 | 3.5 | |||
DC220 | 1.8 | |||
3 | Overcurrent tripping coil | 8 | ||
4 | Energy charging motor | Rated voltage: DC/AC220V
Rated power: 40W |
Reliable tripping under85%-110% rated voltage | |
5 | Closing spring charging time | ≤10s |